LED driver passed safety but missed the efficiency limit at low load
Full-load efficiency was fine. The regulation measures at part load, and that is where the design lost its margin.
Full-load efficiency met the target, but average active efficiency at part load fell below the limit for the product class.
Measured the load points defined by the regulation rather than a single full-load point, identified the bias winding as the part-load loss, and re-measured after the design change.
Part-load efficiency met the limit after the bias change. The existing safety and EMC reports remained valid.
The driver had a safety report and an EMC report, both clean. The efficiency claim came from a full-load measurement the customer had run in-house, which is not the number the regulation asks for.
The gap
Average active efficiency is computed across defined load points. At 10 percent load the driver dropped below the limit for its power class, because the standby controller kept a bias winding energised that the design did not need at low output.
Outcome
The customer changed the bias arrangement and re-ran the efficiency measurements. The safety and EMC reports were unaffected, so no part of the earlier work was wasted.
Frequently asked
Why is full-load efficiency not enough?
Because the regulation averages defined load points, including low load where fixed losses dominate.